Tuesday, August 17th, 2010 at 7:12 am
I have about a 1900 sq. ft. house that is in desperate need of a new heatpump. I finally got a guy to come out and check it out. The old unit both inside and out are done. There is no point in repairing a 30 year old system that keeps breaking. My house is total electric so I’m getting an all electric heat pump. Here is what is offered: A 3.5 ton, 15 Seer American Standard heatpump with a matching variable speed air handler for the inside. I have a concrete slab house so the duct work is all ok after checking. Other than normal installation, they will have to run new refrigerant line from the compressor outside to the handler inside because my old system used R22 and i’m getting 410 with the new system. The guy estimates that it will cost about ,500 for all of it…including a new programmable thermostat. I’m having a hard time swallowing it because I can buy all of the equipment online for about ,500-3000. I just don’t have the knowledge to put it in, nor would there be a warranty if I did it. The warranty after install is for 10 years, and this unit qualifies for the tax deduction rebate by the gov. I live in a small town in Oklahoma and this guy is a certified dealer for American Standard. What do you think? A little pricey??
Related Blogs
Read the rest of this entry
Saturday, August 14th, 2010 at 7:45 am
heaters to turn on in my air handler, during the heat pump defrost mode? I just replaced my closet air handler, from a Goodman to a Payne and tied it into an 10 year old Goodman Heatpump. Everything works fine but my electric heaters do not come on when the heat pump goes into defrost. I am using the original Maple Chase 2 heat & 2 cool thermostat and my heat and cooling temps are good. The only problem is that the electric heat does not come on when the out door unit goes into defrost. However, if I manually switch the thermostat into emergency heat from the thermostat the electric heat works. At this point, I was told that I needed a 24 volt Isolation (double pole / double throw) relay. This makes sense but I am not sure how to wire it up.
During the heating mode, the reversing valve is NOT energized. But in the cooling mode and (defrost) it is. So, I was thinking of utilizing the "O" terminal coming from the defrost board from the out door unit and use it to power up my relay to energize my electric heat relays during defrost. But the problem with that is how do I wire that to an isolation relay and how do I make it bypass the electric heaters relay(s) during a call for cooling since my "O" terminal> reversing valve will then be energized?
Read the rest of this entry
Saturday, July 17th, 2010 at 4:50 pm
Any help would be appreciated because I am trying to use the wireless thermostat to get my 10 month old babies room to hold the correct temperature.
I recenlty purchased a venstar wireless thermostat
VENSTAR T1100RF and am having a issue with the install. Everything on the old and the new seem to line up except on my current thermostat I have a black wire hooked up to E but the new one does not have an E.
Currently I have the following
G- Green wire
C- Blue
R- Red
Y Yellow
W2 white
E- black
O- Orange
I also have a B and L with no wires and a w1 that is connected to the Y2 yellow with a gold plate (maybe it’s a jumper?) but no wires either.
Read the rest of this entry
Monday, July 12th, 2010 at 12:09 am
Please help on wiring my new Honeywell thermostat RTH7500D for heatpump unit(split- heatpump outside and air handler in attic) . The new thermostat has following terminal:
C,G,Y,O/B,RC,R,AUX,E,L
The old Honeywell thermostat model T841a1423. it is a mechanical with mercury in it. there are 6 wires go into theses terminals:Green go to G,Yellow go to Y, Orange go to O, Red go to R, White go to W2,and Black go to X
Please help me wire them and set it up. here is the link to the RTH7500D manual online:
http://yourhome.honeywell.com/yourhome/Applications/TechLit/TechLitSearchResults.aspx
Read the rest of this entry